LDMEDIUM

Low Fire Pressure Switch (Carrier/Bryant)

Low fire pressure switch not closing during modulated heat operation, specific to Carrier and Bryant two-stage and modulating furnaces.

What This Error Code Means

The low-fire pressure switch isn't detecting sufficient draft during low-stage heating.

Common Causes

  • Vent pipe partially blocked
  • Draft inducer motor running slow on low speed
  • Pressure switch hose kinked
  • Defective low-fire pressure switch
  • Excessive vent length or elbows

Affected Brands

CarrierBryant

How ROMA Heating Fixes This

  • Check vent pipe for restrictions
  • Test draft inducer on low speed tap
  • Inspect pressure switch hoses
  • Replace low-fire pressure switch
  • Verify proper operation in both stages