E205HIGH

Pressure Switch Stuck Open

The pressure switch detects inadequate draft inducer vacuum and prevents the furnace from firing to ensure safe exhaust venting.

What This Error Code Means

The pressure switch isn't closing, indicating the draft inducer isn't creating proper negative pressure for safe exhaust.

Common Causes

  • Blocked or frozen vent pipe
  • Failed draft inducer motor
  • Cracked or disconnected pressure switch hose
  • Defective pressure switch
  • Restricted combustion air intake

Affected Brands

LennoxCarrierTraneGoodmanRheemYorkBryant

How ROMA Heating Fixes This

  • Inspect and clear vent and intake pipes
  • Test draft inducer motor operation and amp draw
  • Check pressure switch hoses for cracks or blockages
  • Replace pressure switch if failed
  • Verify proper switch closure after repair

24/7 Emergency Service

Available nights, weekends, and holidays. Fast 1-2 hour response.

Licensed Technicians

TSBC Gas License LGA0202903. Fully insured and WCB covered.

Same-Day Service

We diagnose and fix error code issues quickly.

Seeing Error Code E205?

Call now — our technicians can diagnose and fix it today

Call 778-909-5731