41HIGH

Blower Motor Overload (Lennox)

Lennox furnace blower motor is drawing excessive current or has an open circuit, triggering overload protection.

What This Error Code Means

The blower motor is electrically overloaded or has failed open, preventing proper air circulation.

Common Causes

  • Blower motor seized or failing bearings
  • Failed run capacitor
  • Blower wheel obstructed or unbalanced
  • Motor thermal overload tripped
  • ECM motor module failure

Affected Brands

Lennox

How ROMA Heating Fixes This

  • Check blower wheel for obstructions
  • Test run capacitor
  • Measure motor amp draw against rating
  • Inspect motor bearings and replace if seized
  • Replace motor or ECM module as needed